  • Indoor non expanding steel structure fireproof coating GT-NSF-Fp2.50-HS
Indoor non expanding steel structure fireproof coating GT-NSF-Fp2.50-HS
+

Description

Product Introduction

Indoor non expanding steel structure fireproof coating is the latest product developed by our company. It replaces the previous two-component construction process of thick steel structure fireproof coating, making the construction process simpler and more feasible. It also has strong adhesion and good fire resistance and insulation performance. The fire resistance limit of the 26mm coating thickness can reach 2.5 hours.

Product Composition

Made from composite materials such as expanded vermiculite, high-strength binder, cationic fiber, high-temperature resistant material, and insulation material drying aid, it does not contain volatile harmful substances such as asbestos, methanol, and benzene.

Scope of application

Suitable for fire protection of steel structural components in construction projects.
Fire resistance performance
The coating thickness is 26mm, and the fire resistance limit is not less than 2.5 hours.

Packaging, storage, and transportation

The packaging is made of woven bags, with a net weight of 25 kilograms per bag. During transportation and storage, attention should be paid to moisture prevention, and the shelf life is 6 months.

Construction technology

• Before construction, thoroughly remove rust from the surface of the steel structural components, and then spray two coats of anti rust paint. This coating can be matched with various anti rust paints, such as alkyd anti rust paint or epoxy anti rust paint. Apply the coating after rust prevention is done, that is, when it cannot be easily removed by hand,

• If the anti rust paint layer on the steel substrate is left for too long, remove dust and oil stains before construction;

• Construction should be carried out in an environment with a temperature of (5-40) ℃, relative humidity of (50-80)%, and wind speed of ≤ 5m/s. Steel structures with condensation, frost, and water droplets should not be used for work. During the construction process, rain and direct sunlight should be avoided. Huangmoutian needs to extend the maintenance time to ensure water evaporation;

• The main material for coating construction can be mixed with water on site to ensure no cracking or hollowing. The construction ratio of the base material is powder: water: glue: 1:0.7:0.3. Mix for about 5 minutes and immediately use the spraying method for construction. The thickness should be 1 to 2mm, and the relative humidity should be (50-80)%. Dry for 24 hours until it cannot be moved by hand. The next layer of construction can only be carried out when it is dry.

It should be noted that there should not be too many ingredients in this layer. Just use as much as you want to avoid waste caused by excessive mixing. Master the preparation of the ingredients and use them up within 60 minutes

The main material construction is divided into two types: plastering and spraying

1. The ingredients for wiping are powder: water: glue=1:0.95:0.05, stir for 5 minutes to facilitate the dissolution of solid rubber powder in the powder. Then divide the material into small buckets and apply it, with a thickness of ≤ 10mm, to facilitate moisture distribution and prevent excessive spraying that is not conducive to moisture distribution. Prolonged immersion in water can cause cracking and hollowing of the bottom layer.
2. If using an extrusion pump for material spraying, it is not feasible to mix the ingredients according to the above ratio. In order to facilitate spraying, water needs to be added. Usually, the amount of water added is controlled within the range of increasing by 15%. The purpose is to facilitate spraying without causing sagging due to excessive water addition. For the purpose of facilitating water evaporation, it is advisable to have a thickness of 7 to 10 per application. After the previous application is completed, the next application should be carried out by spraying directly until the thickness required by Party A.

Seriai number Fire resistance time Construction thickness Spray frequency Theoretical dosage lllustrate
1 150min 4mm Ultra thin 10 / thin 4 5kg The thinner the first pass, the better, try tocontrol it to about 0.5mm, about 4 hoursafter the surface is dry, you can apply thesecond pass, after each pass, control it toabout 0.8mm, until the specified thickness.
2 120min 3mm Ultra thin 8 / thin 3 4kg
3 90min 2.1mm Ultra thin 6 / thin 2 3kg
4 60min 1.6mm Ultra thin 4 / thin 2 2kg

Introduce


Hebei Haishang Building Materials Co., Ltd. is a large backbone enterprise in China's fire protection industry. The company covers an area of 16,000 square meters and integrates R&D, production, sales, construction, and consulting services. It has departments such as the Technology Department, production department, quality inspection department, enterprise management department, after-sales service department, Marketing Department, market department, Finance department, and human resources department.

Product  Display
Product Display
Factory building
Plant environment
Factory environment
Workshop environment

Customized Process

Products can be developed and manufactured samples provided by customers.We have an experienced R&D team focused on technological innovation and product upgrades to ensure that product performance is always at the industry-leading level.

Online communication

Provide custom drawings

Merchant quotation

Sign a contract

Processing and production

Packaging and distribution

Confirm receipt of goods

Successful transaction

FAQ


Can you accept small quantities?

Yes, accept small quantity, fast delivery

Do you have pre-shipment inspection procedures?

Yes, we always test the products before delivery.

Can I take samples for testing?

Yes, samples can be sent for testing before bulk ordering.

When is the delivery time?

Inventory orders within 7-15 days, for oem and odm orders, the specific time depends on the actual situation.

What are the terms of payment?

Wire transfer or letter of credit, Western Union, Alipay, etc.

What is the minimum order quantity?

It depends on the product.


  • Indoor non expanding steel structure fireproof coating GT-NSF-Fp2.50-HS
Indoor non expanding steel structure fireproof coating GT-NSF-Fp2.50-HS
+

Indoor non expanding steel structure fireproof coating GT-NSF-Fp2.50-HS

Indoor non expanding steel structure fireproof coating is the latest product developed by our company. It replaces the previous two-component construction process of thick steel structure fireproof coating, making the construction process simpler and more feasible. It also has strong adhesion and good fire resistance and insulation performance. The fire resistance limit of the 26mm coating thickness can reach 2.5 hours.

WhatsApp:

You still doubt it?  First get samples contact us!

Related Products

Outdoor expansion type steel structure fireproof coating GT-WSP-Fp1.50-HS

Fire protection coating applicable to various load-bearing structures such as steel components and spherical grids in construction engineering

Indoor expansion type steel structure fireproof coating GT-NSP-Fp1.50-J0

Suitable for fire protection coatings of various steel components, spherical grids and other load-bearing structures in construction engineering,

Tunnel fireproof coating SH-HS

It is mainly suitable for fire prevention in highway tunnels and railway tunnels, as well as for fire prevention needs in petrochemical engineering, high-rise buildings, steel structures, and underground garages.

Outdoor non expanding steel structure fireproof coating GT-WSF-Fp2.00-HS

Suitable for fire protection of steel structural components in construction projects.

Immediate consultation

If you are interested in our products, please leave your email, we will contact you as soon as possible, thank you!

Submit Message